  "revision": "F9",
  "date": "2026-10-10",
  "baselineCommit": "236f5a48d96e3c7ea190a2d7e8cbbf2acc439054",
  "status": "PASS",
  "checks": [
    {
      "name": "All F8 wall apertures, home ownership, entrances and loggia cuts retained",
      "status": "PASS"
    },
    {
      "name": "46 homes and 300 sf of private loggias retained; no claimed bay-area addition",
      "status": "PASS"
    },
    {
      "name": "4200 geometry and materials unchanged from the synchronized source",
      "status": "PASS"
    },
    {
      "name": "All geometry finite and triangulable at 2, 4 and 6 stories",
      "status": "PASS"
    },
    {
      "name": "No window on party/shared walls and no facade trim over an opening center",
      "status": "PASS"
    },
    {
      "name": "Deep flat glazing remains 10 inches behind the street wall",
      "status": "PASS"
    },
    {
      "name": "Oriel side lights are glass with complete side frames; aprons have modeled recesses",
      "status": "PASS"
    },
    {
      "name": "Both loggia stacks retain true voids, clear 10-ft front widths and 5-ft depths",
      "status": "PASS"
    },
    {
      "name": "All three street entrances have both portal jambs outside their clear openings",
      "status": "PASS"
    },
    {
      "name": "Repeated floor stripes and miniature top-floor arches removed in F9",
      "status": "PASS"
    }
  ],
  "scope": "Architectural director revision of 4500 Indiana only: clearer vertical oriels and tall divided lights, recessed brick bay aprons, quiet brick piers, continuous ground-floor base, stepped cornice, framed chamfer loggias and restored entry portals. F8 apertures, 10 \u00d7 5 ft loggia reservations, 10-inch flat-window recesses, 46 homes and floor areas retained.",
  "homes": 46,
  "privateLoggiaSfPerFloor": 100.00000000000006,
  "privateLoggiaSfProject": 300.00000000000017,
  "projectApartmentSf": 41827.333333333336,
  "enclosedSf": 45856.000000000015,
  "openSf": 7266.666666666665,
  "upperStreetBays": 12,
  "upperStreetFlat": 12,
  "windowCount": 188,
  "loggiaCount": 6,
  "meshFaces": 32937,
  "limits": [
    "Geometric checks do not establish architectural acceptance, daylight performance, code or construction compliance.",
    "Upper room layouts remain unfitted. The saved building, stair and parcel exceptions remain.",
    "Bay floor area, structural support, public-way projections, weathering, guards and detailed facade cost remain unresolved and excluded from the saved area/cost model.",
    "Site/RFP inputs and existing GIS context retained; no new survey supplied."
  ],
  "visualReview": {
    "status": "Reviewed by architectural director",
    "views": [
      "Street oblique",
      "Masonry detail",
      "Additional oblique chamfer view"
    ],
    "findings": "Vertical bays, framed glazing, entry jambs and loggia returns read clearly; no further geometry changes required for this concept pass.",
    "scope": "Project-specific design proposal, not a user-adopted universal style rule."
  }
}